UScreen Tests: Your Trusted Drug Screening Experts for Over 20 Years

Free FedEx Ground Shipping with $150 Order

UScreen™ 12 Panel Drug Test Cup with Adulterants, AMP, BUP, BZO, COC, ETG/Alcohol, FEN, MET/mAMP, MDMA, MOP, MTD, OXY, THC + CR, SG, PH | USSCUPFA-12EF3, 25/Box

Write a Review
SKU:
USSCUPFA-12E3F
MPN:
USSCUPFA-12E3F

Bulk discount rates

Below are the available bulk discount rates for each individual item when you purchase a certain amount

Quantity Per Item
1 - 3 $116.25
4+ $110.50
  • UScreen+™ 12 Panel Rapid Drug Screen Cup USSCUPFA-12E3F
  • UScreen+™ 12 Panel Rapid Drug Screen Cup USSCUPFA-12E3F
  • UScreen+™ 12 Panel Rapid Drug Screen Cup USSCUPFA-12E3F
  • UScreen Plus™ 12 Panel Rapid Drug Screen Cup USSCUPFA-12E3F
$116.25
Frequently bought together:

Description

UScreen™ Rapid Urine Drug Test Cup, 12-Panel Drug Screening Test Cup with EtG Alcohol, Fentanyl, and Adulterants, USSCUPFA-12E3F

The UScreen Plus™ Cup is Back! Say goodbye to the long wait times for drug test results! Introducing UScreen+™ – your go-to for fast, reliable drug testing. With our innovative UScreen+™ Urine Drug Test Cup, you'll receive negative results with a clear, solid line in just 90 seconds or less. Our comprehensive UScreen+™ Urine Drug Test Kit covers testing for 12 drugs of abuse. Exclusive distribution by TransMed Company guarantees quality and accessibility.

This Highest Quality drug test cup is an easy, fast, qualitative method for screening without the need of instrumentation. The Uscreen+™ Rapid Drug Test Cup is a single step, fully integrated, self contained cup used for the simultaneous, qualitative detection of multiple drug metabolites at specific cutoff levels in human urine. No tipping or turning required for activation and results can be read in 5 minutes.

New And Improved Features

★ Results Remain Valid for 60 Minute Read Time
★ Click Seal Cap - Insures Cap is Securely Tightened
★ Control & Test Lines are 10% Wider Than the Leading Competitors

UScreen+ Features & Benefits

  • Easier to Handle Full Size 4-Sided Cup
  • For Forensic Use
  • Sold in boxes of 25 tests
  • 99% Accuracy Rate
  • Adheres to the SAMHSA Cutoff Levels
  • Easy to Read Results in 5 minutes—results are stable for 60 minutes
  • Easy one-step operation
  • Zero exposure to donor specimen
  • Donor friendly cup opening
  • Fast Dark Test lines
  • Most results within 60-90 seconds!
  • Built in Adulteration Test / Specimen Validity Tests (SVT)—helps to monitor specimen tampering
  • Dual scale °F/°C Temperature Strip verifies if urine is "fresh" and not diluted
  • Self-contained cup is ideal for sending preliminary positive specimens to the lab for confirmation
  • Simple to use, no need to tilt cup to activate test—read results at 5 minutes

UScreen Plus Product Information & Reference Materials

Download UScreen PDF Reference DocumentationUScreen+ Drug Test Cup Brochure

Download UScreen PDF Reference DocumentationUScreen+ Drug Test Cup Package Insert (FUO Version)

12 Panel Configuration with Adulteration
Item Number Drugs Screened Adulterants Screened Regulatory Approvals
USSCUPFA-12E3F AMP1000, BUP10, BZO300, COC300, ETG300, FEN10, mAMP1000, MDMA500, MTD300, MOP300, OXY100, THC50 CR - Creatinine
SG - Specific Gravity
PH - pH Level
Forensic Use

Performing the Test

  1. Remove the test cup from the foil pouch by tearing at the notch and use it as soon as possible. Open the cap of the test cup and void directly into the test cup to reach the minimum urine level.
  2. Verify that temperature is within range on the temperature strip (90° – 100°F).
  3. To activate test, place the screw-top lid on the cup and turn until tight.
  4. Remove label.  For cups with specimen validity tests (adulteration controls), compare each of the specimen validity test pads with the corresponding color blocks on the enclosed color chart.  If pad colors are outside normal range, open a second test cup, collect a new specimen, and retest.
  5. Read the drug screen test results when control lines are clearly visible.

Interpreting the Test Results
Negative (-) Preliminary Positive (+) Invalid

A negative result is indicated by the presence of both a “C” control line or and a “T” test line for each designated drug.

If a color band is visible in each control region "C" and the appropriate drug test region "T", it indicates that the concentration of the corresponding  drug  of  that  specific  test region is absent or below the detection limit of the test.

The presence of a “C” control line and a very light “T” test line indicates a negative result.  Any indication of a “T” test line is interpreted as a negative result. There is no meaning attributed to line color intensity or width. Any visible line is considered to be a line.

A positive result is indicated by the presence of a “C” control line and the absence of a “T” test line.

A color band is visible in each control region "C". If no color band appears in the appropriate drug test region "T", a preliminary positive result is indicated for the corresponding drug of that specific test region.

An invalid result is indicated when the “C” line is completely missing from one or more test windows. If this happens, run another test.

If a color band is not visible in the control region "C", the test is invalid. Another test should be run to re-evaluate the specimen. If test still fails, please contact the distributor or the store, where you bought the product, with the lot number.

Interpreting UScreen 12 Panel Urine Drug Test ResultsUScreen+ Intrepretation of Test Lines
Urine Drug Panel Detection Options
Multi-Drug Urine Test Cup is an immunoassay for the qualitative determination of single or multiple drugs in human urine at the cutoff concentrations of table below
Drug (Identifier) Calibrator Cut-off Level Minimum Detection Time Maximum Detection Time
Amphetamine (AMP 1000) d-Amphetamine 1000 ng/mL 2-7 hours 1-2 days
Amphetamine (AMP 500) d-Amphetamine 500 ng/mL 2-7 hours 1-2 days
Secobarbital (BAR) [Barbiturates] Secobarbital 300 ng/mL 2-4 hours 1-4 days
Buprenorphine (BUP) Buprenorphine 10 ng/mL 4 hours 1-3 days
Oxazepam (BZO) [Benzodiazapines] Oxazepam 300 ng/mL 2-7 hours 1-2 days
Cocaine (COC 300) Benzoylecgonine 300 ng/mL 1-4 hours 2-4 days
Cocaine (COC 150) Benzoylecgonine 150 ng/mL 1-4 hours 2-4 days
EDDP (Methadone Metabilite) 2-ethylidene-1,5- dimethyl-3,3- diphenyl- pyrrolidine 300 ng/mL 3-8 hours 1-3 days
Methylenedioxymetham- phetamine (MDMA) [Ecstasy] 3,4-Methylenedi- oxymethamphe- tamine 500 ng/mL 2-7 hours 2-4 days
Ethyl Glucuronide (ETG) [Alcohol Metabolite] Ethyl Glucuronide 300 ng/mL 2-3 hours 3-4 days
Fentanyl (FYL / FEN) Fentanyl 10 ng/mL 2-7 hours 1-3 days (chronic use: up to 4 days)
Heroin Metabolite (6-MAM) 6-Monoacetyl- morphine 10 ng/mL 2-8 hours 1-3 days
Ketamine (KET) Ketamine 1000 ng/mL 1-4 hours 1-3 days (chronic use: up to 5–7 days)
Kratom (KRA) Mitragynine 300 ng/mL 1-2 hours 1-2 days (chronic use: up to 5–7 days)
Methamphetamine (MET 1000) [Meth] D(+)-Methamph- etamine 1000 ng/mL 2-7 hours 2-4 days
Methamphetamine (MET 500) [Meth] D(+)-Methamph- etamine 500 ng/mL 2-7 hours 2-4 days
Opiates (OPI 2000) Morphine 2000 ng/mL 2 hours 2-3 days
Morphine (MOP 300) Morphine 300 ng/mL 2 hours 2-3 days
Methadone (MTD) Methadone 300 ng/mL 3-8 hours 1-3 days
Oxycodone (OXY) Oxycodone 100 ng/mL 4 hours 1-3 days
Phencyclidine (PCP) Phencyclidine 25 ng/mL 4-6 hours 7-14 days
Propoxyphene (PPX) d-Propoxyphene 300 ng/mL 2 hours 2-3 days
Synthetic Cannabis (K2) JWH-018 / JWH-073 20 ng/mL 2-6 hours 1-3 days (chronic use: up to 10 days)
Tramadol (TRA) Tramadol 100 ng/mL 2-4 hours 1-2 days (chronic use: up to 4 days)
Nortriptyline (TCA) [Tricyclic Antidepressants] Nortriptyline 1000 ng/mL 8-12 hours 2-7 days
Cannabinoids (THC) [Marijuana] 11-nor-∆9-THC- 9-COOH 50 ng/mL 2 hours up to 5+ days
This test is intended for forensic use (FUO) and is for in vitro diagnostic purposes only. The test provides preliminary results and should not be used as the sole basis for determining the presence of drugs of abuse. Clinical consideration and professional judgment are essential, particularly when evaluating a preliminary positive result.
 
To confirm the results, a more specific chemical method is required. Gas chromatography/mass spectrometry (GC/MS) or liquid chromatography/mass spectrometry (LC/MS) is the recommended confirmatory method.
 
Detection times are approximate and can vary significantly based on several factors, including individual metabolism, frequency and quantity of substance use, hydration levels, body mass, age, overall health, and the sensitivity and specificity of the testing method. These times are for informational purposes only and should not be considered definitive or guaranteed. Always refer to the drug test manufacturer’s package insert for specific detection window information.
Adulteration Control Panels (see configuration above)
Creatinine (CRE) Daily creatinine excretion, related to muscle mass of the human body, is usually constant. The DOT guideline states that urine specimens with creatinine levels of less than 20 mg/dl are indications of adulteration. Although these ranges are affected by age, sex, diet, muscle mass and local population distribution2, sample with creatinine level of lower than 20 mg/dl should be considered adulterated.
Glutaraldehyde (GLU) Glutaraldehyde is not a natural component of human urine and it should not be present in normal urine. The presence of glutaraldehyde in the urine sample indicates the possibility of adulteration. However, false positive may result when ketone bodies are presence in urine. Ketone bodies may appear in urine when a person is in ketoacidosis, starvation or other metabolic abnormalities.
Nitrite (NIT) Nitrite (NIT): Although nitrite is not a normal component of urine, nitrite levels of up to 3.6 mg/dl may be found in some urine specimens due to urinary tract infections, bacterial contamination or improper storage. In this adulteration control, nitrite level above 7.5 mg/dl is considered abnormal.
PH Level (pH) Normal urine pH ranges from 4.5 to 8.0. Values below pH 4.0 or above pH 9.0 are indicative of adulteration. TEST LIMITATIONS QUESTIONS AND ANSWERS 1. This test has been developed for testing urine samples only. No other fluids have been evaluated. DO NOT use this device to test specimen other than urine. 2. Technical or procedural errors, as well as interfering substances in the urine specimen may cause incorrect results. 3. Contaminated or adulterated urine samples may produce incorrect results. Strong oxidizing agents such as bleach (hypochlorite) can oxidize drug analyte. If a sample is suspected, repeat the test with another urine sample.
Specific Gravity (S.G.) Random urine may vary in specific gravity from 1.003 - 1.030. Normal adults with normal diets and normal fluid intake will have an average urine specific gravity of 1.016 - 1.022. Elevated urine specific gravity value may be obtained in the presence of moderate quantities of protein. DOT guidelines state that a urine specimen with specific gravity level of less than 1.003 is an indication of adulteration. Specific gravity and creatinine values should be considered together to provide a better picture of whether the sample is adulterated.
Oxidants (OXI) The presence of Bleach and other oxidizing reagents in the urine is indicative of adulteration since oxidizing reagents are not normal constituents of urine. Other oxidizing reagents include Hydrogen Peroxide, Ferricyanide, Persulfate, Pyridinium Chlorochromate…etc.
Pyridinium Chlorochromate (PCC) The presence of any chromate in urine is indicative of adulteration as chromate is not a normal constituent of urine.

We have been serving clients from all industries for 20 years! We offer high quality products, competitive prices and superior customer service.

View AllClose

Additional Information

Per Each:
25
View AllClose